Metering
1. Supported Eichrecht meters (Germany & Austria)
The meters listed here can be set up to be Eichrecht-compliant, but can also be used as general-purpose meters.
Manufacturer | Model | Label in Config UI | Connection/Protocol | Cable loss factor | Duration-based invoicing | Supported from | Note |
---|---|---|---|---|---|---|---|
EMH | eHZ generation K | eHZ Meter | RJ10 / SML | Not possible | Not possible | 4.xx | Eichrecht with CC612 only |
eHZB | eHZ-B Meter | RJ10 / SML | Not possible | Not possible | 5.32.0 | ||
Eastron | SDM 630 EV | ER Eastron SDM630-EV | Modbus RTU | Possible | Not possible | 5.33.2 | |
NZR | EcoCount SL+SC 85 | ER NZR EcoCount SL+SC 85 | Modbus RTU | Possible | Not possible | 5.33.1 | |
EcoCount SL+S 85 | ER NZR EcoCount SL+S 85 | Modbus RTU | Not possible | Not possible | 5.33.1 | ||
ISKRA | WM3M4C | ER Iskra WM3M4C | Modbus RTU | Possible | Not possible | 5.33.1 | |
Gossen Metrawatt | EM2289 | Meter Modbus | Modbus RTU | Possible | Possible | 5.21.1 | Customer-specifc meter type |
DZG | DVH 4013 | Meter Modbus | Modbus RTU | Possible | Possible | 5.21.1 | Eichrecht with CC612/CC613 only |
DWH 4013 | Meter Modbus | Modbus RTU | Possible | Possible | 5.21.1 | ||
DWH 4113 | Meter Modbus | Modbus RTU | Possible | Possible | 5.23.0 |
2. Supported general-purpose meters
Manufacturer | Model | Label in Config UI | Connection/Protocol | Supported from | Additional info |
---|---|---|---|---|---|
ABB | B23 | Modbus Meter ABB | Modbus RTU | ||
D1M | Modbus ABB D1M | Modbus RTU | 5.33.0 | ||
D1M | Modbus ABB D1M (TCP) | Ethernet Modbus TCP | 5.33.0 | ||
EV3 | Modbus ABB EV3 | Modbus RTU | |||
BERG | B23 | Modbus Berg B23 | Modbus RTU | ||
BME 461 | Modbus Berg BME 461 | Modbus RTU | |||
Carlo Gavazzi | EM111 | Modbus Meter Carlo Gavazzi EM111/112 | Modbus RTU | ||
EM112 | Modbus Meter Carlo Gavazzi EM111/112 | Modbus RTU | |||
EM200 | Modbus Meter Carlo Gavazzi EM200 | Modbus RTU | |||
EM210 | Modbus Meter Carlo Gavazzi EM210 | Modbus RTU | |||
EM340 | Modbus Meter Carlo Gavazzi EM340 | Modbus RTU | |||
DZG | DVH4013 | Modbus DZG DVH4013 | Modbus RTU | ||
DWH4113 | Modbus DZG DWH4113 | Modbus RTU | 5.33.1 | ||
Eastron | SDM 120 | Modbus Eastron SDM120_220 | Modbus RTU | ||
SDM 220 | Modbus Eastron SDM120_220 | Modbus RTU | |||
SDM 630 | Modbus Meter Eastron SDM630 | Modbus RTU | |||
SDM 630-EV | ER Eastron SDM630-EV | Modbus RTU | 5.33.1 | ||
SDM72D-M | Modbus Eastron SDM72D | Modbus RTU | |||
SDM72D-M v2 | Modbus Eastron SDM72D-M-V2 | Modbus RTU | 5.40.0 | ||
ECS | M3PRO | Modbus ECS M3PRO | Modbus RTU | 5.32.0 | |
M3PRO | Modbus ECS M3PRO (TCP) | Ethernet Modbus TCP | 5.32.0 | ||
Eetarp | GEM230 | Modbus Eetarp GEM230 | Modbus RTU | 5.33.0 | |
GEM630 | Modbus Eetarp GEM630 | Modbus RTU | 5.33.0 | ||
EMH | eHZ generation K | eHZ Meter | RJ10 / SML | Interface only present on CC612 | |
eHZB | eHZ-B Meter | RJ10 / SML | 5.32.0 | ||
Finder | 7E.x8 | Modbus Meter Finder | Modbus RTU | ||
7M38 | Modbus Meter Finder 7M38 | Modbus RTU | |||
Garo | EM270 | Modbus Meter Garo EM270 | Modbus RTU | ||
GM3T | Modbus Meter Garo GM3T | Modbus RTU | |||
GMI3D LP | Modbus Meter Garo GMI3D-LP | Modbus RTU | |||
GNM1D | Modbus Meter Garo GNM1D | Modbus RTU | |||
GNM3D | Modbus Meter Garo GNM3D | Modbus RTU | |||
GNM3T | Modbus Meter Garo GNM3T | Modbus RTU | |||
GNM3TD | Modbus Meter Garo GNM3TD | Modbus RTU | |||
Gossen Metrawatt | EM2289 | Meter Modbus | Modbus RTU | ||
Hager | ECR380D | Modbus Hager ECR380D | Modbus RTU | ||
IME | CE4DF3DTMID | Modbus IME CE4DF3DTMID | Modbus RTU | ||
CE4DMID31 | Modbus IME CE4DMID31 | Modbus RTU | |||
INEPRO | PRO1 | Modbus Inepro PRO1_2 | Modbus RTU | ||
PRO2 | Modbus Inepro PRO1_2 | Modbus RTU | |||
PRO380 | Modbus Inepro PRO380 | Modbus RTU | |||
Iskra | IE38M | Modbus Iskra IE38M | Modbus RTU | ||
WM3M4C | ER Iskra WM3M4C | Modbus RTU | 5.33.1 | ||
WM3M6 | Modbus Iskra WM3M6 | Modbus RTU | |||
Janitza | UMG 512PRO | Modbus Janitza UMG 512/96 PRO | Modbus RTU | ||
UMG 512PRO | Modbus Janitza UMG 512/96 PRO (TCP) | Ethernet Modbus TCP | |||
UMG 604PRO | Modbus Janitza UMG 604 PRO (TCP) | Ethernet Modbus TCP | 5.32.0 | Default Modbus ID: 1 | |
UMG 605PRO | Modbus Janitza UMG 605 PRO | Modbus RTU | |||
UMG 605PRO | Modbus Janitza UMG 605 PRO (TCP) | Ethernet Modbus TCP | |||
UMG 96PRO | Modbus Janitza UMG 512/96 PRO | Modbus RTU | |||
UMG 96PRO | Modbus Janitza UMG 512/96 PRO (TCP) | Ethernet Modbus TCP | |||
Lovato | DMED 301 | Modbus Lovato DMED 301 | Modbus RTU | 5.33.1 | |
Mennekes | EV OPTIMIZER | EV Optimizer | Ethernet Modbus TCP | ||
NZR | EcoCount S85 | Modbus NZR EcoCount S85/SL85 | Modbus RTU | ||
EcoCount SL+S 85 | ER NZR EcoCount SL+S 85 | Modbus RTU | 5.33.1 | ||
EcoCount SL+SC 85 | ER NZR EcoCount SL+SC 85 | Modbus RTU | 5.33.1 | ||
EcoCount SL85 | Modbus NZR EcoCount S85/SL85 | Modbus RTU | |||
OPTEC | Modbus Optec | Modbus RTU | |||
Phoenix Contact | EEM EM357 | Modbus Phoenix Contact EEM-EM357 | Modbus RTU | ||
EMpro EEM MB371 | Modbus Phoenix Contact EEM-MB371 (TCP) | Ethernet Modbus TCP | |||
Saia | ALE3 | Modbus Saia ALE3 | Modbus RTU | Set parity to even | |
Schneider Electric | iEM3555 | Modbus Schneider iEM3555 | Modbus RTU | ||
Schneider Generic | Modbus Schneider Generic | Modbus RTU | 5.33.1 | Generic implementation for Schneider Electric meter | |
Schneider Generic (TCP) | Modbus Schneider Generic (TCP) | Ethernet Modbus TCP | 5.33.1 | ||
SELEC | EM2M-1P-C-100A | Modbus SELEC EM2M-1P-C-100A | Modbus RTU | 5.32.0 | |
Siemens | 7KM2200 | Modbus Siemens 7KM2200 (TCP) | Ethernet Modbus TCP | ||
7KT1666 | Modbus Siemens 7KT1666 | Modbus RTU | |||
SMA | Commercial Energy Meter | SMA Commercial Energy Meter (TCP) | Ethernet Modbus TCP | 5.33.1 | |
Temco Controls | SPM1-XX0-AC | Modbus Temco Controls SPM1-XX0-AC | Modbus RTU | 5.33.1 | |
TQ | EM300LR | Modbus TQ EM300-LR | Modbus RTU | ||
EM410 | Modbus TQ EM410/EM420 | Modbus RTU | |||
EM420 | Modbus TQ EM410/EM420 | Modbus RTU | |||
EM300LR | Modbus TQ EM300-LR (TCP) | Ethernet Modbus TCP | |||
EM410 | Modbus TQ EM410/EM420 (TCP) | Ethernet Modbus TCP | |||
EM420 | Modbus TQ EM410/EM420 (TCP) | Ethernet Modbus TCP | |||
WAGO | 879 3000 | Modbus Wago 879-3000 | Modbus RTU | 5.32.0 | |
Walther Werke | IPD CONTROL | Modbus IPD Control (TCP) | Ethernet Modbus TCP | 5.29.1 | |
YTL | DTS353F | Modbus YTL DTS353F | Modbus RTU | 5.32.0 | |
S0 Meter | Any model | S0 Meter Opto | S0 pulse meter | Default: 1000 pulses/kWh Not recommended | |
WiMOD | IR Reader USB stick | WiMOD IR Reader USB stick | eHZ meter | Second meter only |