The new ISOMETER® iso415R is a simple and intelligent ground-fault monitor for electrical safety in control circuits and other applications. It is for ungrounded systems for compliance with IEC 60364-4, and meets IEC 61557-8 requirements. It combines easy operation, multiple interfaces, flexible application options and a compact design. It is the first device of Bender's new SmartDetect series and offers maximum safety in ungrounded AC, AC/DC, and DC systems.
Fast, simple operation was a central goal in the development of the new iso415R. That is why the parameters of the ISOMETER® can be set either with two rotary potentiometers, with the Bender Connect app, or with Modbus RTU communications. With the app, the iso415R can be set up before installation. In addition, a setting made once can be transferred to any number of devices. All technical information including the manual can be conveniently accessed at any time via the QR code. The measured value is displayed by LEDs. The device, which is only 18 mm (0.7”) wide, is installed by simply pushing it into place on a DIN rail.
With the NFC function and the Bender Connect App you can easily configure the iso415R via a smartphone.
The new ISOMETER® iso415R is a simple and intelligent ground-fault monitor for electrical safety in control circuits and other applications. It is for ungrounded systems for compliance with IEC 60364-4, and meets IEC 61557-8 requirements. It combines easy operation, multiple interfaces, flexible application options and a compact design. It is the first device of Bender's new SmartDetect series and offers maximum safety in ungrounded AC, AC/DC, and DC systems.
Fast, simple operation was a central goal in the development of the new iso415R. That is why the parameters of the ISOMETER® can be set either with two rotary potentiometers, with the Bender Connect app, or with Modbus RTU communications. With the app, the iso415R can be set up before installation. In addition, a setting made once can be transferred to any number of devices. All technical information including the manual can be conveniently accessed at any time via the QR code. The measured value is displayed by LEDs. The device, which is only 18 mm (0.7”) wide, is installed by simply pushing it into place on a DIN rail.
With the NFC function and the Bender Connect App you can easily configure the iso415R via a smartphone.
1 Only adjustable via Modbus RTU or Bender App.
Type | Supply voltage Us | Nominal system voltage Un | Art. No. |
---|---|---|---|
iso415R-24 | DC 24 V | AC 0…415 V / DC 0…400 V | B71602000* |
iso415R-2 | AC/DC 100…240 V | (3)AC 100…240 V, 3NAC 100…415 V / DC 100…240 V | B71603000 |
* An additional power supply is required for the device version iso415R-24
Power supply
Type | Rated input voltage UIN | Rated voltage | Art. No. |
---|---|---|---|
STEP-PS/1 AC/24 DC/0.5 | AC 85…264 V, 45…65 Hz; DC 95…250 V | DC 24 V | B94053110 |
For the device version iso415R-24 (B71602000), an additional power supply is required
Name | Category | Size | Language | Timestamp | D-/B-Number |
---|---|---|---|---|---|
RoHS/REACH Report - B71602000 | RoHS/REACH Report | 260.7 KB | 2024/09/0606.09.2024 | ||
Länderliste Funkzulassungen/Countries with RF Approval | Technical information | 83.8 KB | 2024/12/0202.12.2024 | ||
UKCA - iso410_415_420 | Declarations of Conformity | 121.3 KB | 2023/06/2929.06.2023 | ||
iso410_415_420 | CE Declarations of conformity | 82.4 KB | 2023/06/2929.06.2023 | ||
iso415R-x | Quickstarts | 2.3 MB | DE | 2024/05/2929.05.2024 | D00401 |
iso415R-x | Quickstarts | 2.3 MB | EN | 2024/05/2929.05.2024 | D00401 |
iso415R-x | Datasheets | 465.1 KB | DE | 2022/09/1313.09.2022 | D00401 |
iso415R-x | Datasheets | 458.4 KB | EN | 2022/09/1313.09.2022 | D00401 |
iso415R-x | Manuals | 2.4 MB | DE | 2022/07/2121.07.2022 | D00401 |
iso415R-x | Manuals | 2.4 MB | EN | 2022/07/2121.07.2022 | D00401 |
iso415R | Flyer | 616.6 KB | EN | 2021/07/0707.07.2021 | D00401 |
iso415R | Flyer | 933.0 KB | DE | 2021/06/2929.06.2021 | D00401 |
iso415R | Flyer | 932.9 KB | EN | 2021/06/3030.06.2021 | D00401 |
iso415R | Flyer | 555.9 KB | ES | 2021/07/0909.07.2021 | D00401 |
Software information | Technical information | 33.8 KB | EN | 2022/09/1313.09.2022 |