The NGRM500 is only intended for use in high-resistance grounded systems. In these systems, the NGRM500 monitors:
In order to meet the requirements of applicable standards, customised parameter settings must be made on the device to configure it for local equipment and operating conditions.
The NGRM500 is only intended for use in high-resistance grounded systems. In these systems, the NGRM500 monitors:
In order to meet the requirements of applicable standards, customised parameter settings must be made on the device to configure it for local equipment and operating conditions.
Type | Supply voltage US / Frequency range Hz | Art. No. |
---|---|---|
NGRM500 | AC 48…240 V, 40…70 Hz DC 48…240 V | B94013500 |
CD-series coupling device
Type | Voltage Usys | Art. No. |
---|---|---|
CD1000 | 400…690 V | B98039010 |
CD1000-2 | 400…1000 V | B98039053 |
CD5000 | 1000…4200 V | B98039011 |
CD14400 | 4300…14550 V | B98039054 |
CD25000 | 14551…25000 V | B98039055 |
Measuring current transformer
Type | Voltage/Current | Art. No. |
---|---|---|
CTAC35 CTAC60 CTAS50 CTAS80 CTAS120 | AC up to 30 A | B98110007 B98110017 B98110009 B98110010 B98110011 |
CTUB103-CTBC35 | AC/DC up to 10 A | B78120030 |
CTUB103-CTBC60 CTUB103-CTBC120 | AC/DC up to 25 A | B78120031 B78120032 |
CTB31…CTB51 series | AC > 30…1000 A | B980860xx |
Voltage supply for measuring current transformers CTUB103…
Type | max. connected measuring current transformers | Art. No. |
---|---|---|
STEP-PS/1 AC/24 DC/0.5 | 2 | B94053110 |
STEP-PS/1 AC/24 DC/1.75 | 7 | B94053111 |
STEP-PS/1 AC/24 DC/4.2 | 17 | B94053112 |
Name | Category | Size | Language | Timestamp | D-/B-Number |
---|---|---|---|---|---|
NGRM500 Update V4.00 | Software | 8.1 MB | 2024/04/2323.04.2024 | ||
NGRM | CE Declarations of conformity | 88.5 KB | 2023/05/0303.05.2023 | ||
NGR Product Comparison | Flyer | 630.6 KB | EN | 2022/07/1818.07.2022 | |
NGRM…-Modbus | Manuals | 453.9 KB | DE | 2022/06/0909.06.2022 | D00292 |
NGRM…-Modbus | Manuals | 443.2 KB | EN | 2022/06/0909.06.2022 | D00292 |
How to Size an NGR (US) | Technical information | 424.0 KB | EN | 2019/05/1313.05.2019 | |
NGRM500/NGRM550 | Datasheets | 1.2 MB | DE | 2023/06/2020.06.2023 | D00373 |
NGRM500/NGRM550 | Quickstarts | 1.1 MB | DE | 2024/02/0707.02.2024 | D00373 |
NGRM500/NGRM550 | Quickstarts | 1.1 MB | EN | 2024/02/0707.02.2024 | D00373 |
NGRM500/NGRM550 | Manuals | 7.4 MB | DE | 2024/09/1818.09.2024 | D00373 |
NGRM500/NGRM550 | Manuals | 7.4 MB | EN | 2024/09/1818.09.2024 | D00373 |
NGRM500/NGRM550 | Datasheets | 1.2 MB | FR | 2023/06/2020.06.2023 | D00373 |
NGRM500 Guideform Specification (US) | Technical information | 141.3 KB | EN | 2020/04/3030.04.2020 | |
NGRM500 Guideform Specifications | Technical information | 158.7 KB | ES | 2020/05/2222.05.2020 | |
NGRM…-Modbus | Manuals | 463.4 KB | ES | 2022/06/0909.06.2022 | D00292 |
NGR Checklist (US) | Technical information | 245.3 KB | EN | 2022/11/0707.11.2022 | |
Guideline on NGR/Safety Ground Monitoring | Technical information | 234.7 KB | EN | 2019/09/2020.09.2019 | |
NGRM500 Retrofit Guide (US) | Technical information | 1.3 MB | EN | 2021/02/1010.02.2021 | |
How to size an NGR (ES) | Technical information | 426.7 KB | ES | 2021/05/2626.05.2021 | |
Guideline on NGRM Relay Testing | Technical information | 522.3 KB | EN | 2021/10/2626.10.2021 | |
HRG & LRG Systems (US) | Product Brochures | 3.6 MB | EN | 2024/01/0303.01.2024 | |
Neutral Grounding Resistor Monitors (US) | Flyer | 343.7 KB | EN | 2020/03/2323.03.2020 | |
NGRM500/NGRM550 | Datasheets | 1.2 MB | EN | 2023/06/2020.06.2023 | D00373 |
NGRM550 & NGRM750 | Flyer | 630.6 KB | EN | 2022/05/2525.05.2022 |