Control voltage circuits must be monitored for electrical safety; after all, an undetected electrical fault is as significant as unexpected system downtime and also significantly increases the fire risk. At the same time, unplanned service interventions can be expensive and time-consuming. Some transformer station insurers also demand effective condition monitoring systems. The Bender condition monitoring system gives you a clear overview of all the relevant data for your system.
An uninterruptible power supply (UPS) is used to ensure the supply of critical electrical loads in the event of problems in the power supply. The UPS systems (normally battery or oscillating weight systems) bridge the period until the emergency power systems (generators) are activated or the network is available again. Electrical safety is continuously monitored by Bender products, including offline monitoring.
The VMD258 analogue voltage relay monitors three-phase AC systems for under and overvoltage (window function). It does not need a neutral point connection and is therefore suitable for all 3AC systems. The supply voltage of the electronics is taken from the system to be monitored. The supply for the electronics, the relays and the connection for the external energy store are separated from the system with dual insulation. Special input transformers muffle the transfer of interference factors from the system. The response values for under and overvoltage and for response delays can be adjusted to any level.
Name | Category | Size | Language | Timestamp | D-/B-Number |
---|---|---|---|---|---|
Power Quality/Measuring and monitoring relays | Product Overviews | 2.7 MB | EN | 2022/05/2525.05.2022 | |
Product Overview ISOMETER®/ISOSCAN® | Product Overviews | 5.3 MB | EN | 2024/02/1616.02.2024 | |
Product Overview - Residual Current Monitoring | Product Overviews | 6.3 MB | EN | 2024/10/2929.10.2024 | |
Power Quality | Flyer | 468.0 KB | EN | 2022/12/1414.12.2022 | |
Power Plants | Market Segment Brochures | 5.2 MB | EN | 2024/03/0606.03.2024 | |
EDS309x | Application note | 1.4 MB | EN | 2019/05/1313.05.2019 | D00012 |
Insulation Fault Location - Planning and Setup | Technical article | 112.4 KB | EN | 2019/05/1313.05.2019 | |
Electrical Safety in Control and Auxiliary Circuits | Technical article | 632.6 KB | EN | 2019/05/1313.05.2019 | |
Where Residual Current Technology Meets the IT System | Technical article | 353.8 KB | EN | 2019/05/1313.05.2019 |
Products
Undervoltage/overvoltage relay for monitoring three-phase AC systems (window discriminator function)
Insulation monitoring device for inverter applications and large industrial plants
Insulation monitoring device for unearthed AC/DC control circuits
Insulation fault locator for localisation of insulation faults in main circuits
Insulation fault locator for localisation of insulation faults in control circuits
- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.
- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.
- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.
- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.
- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.
- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.
- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.
- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.
- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.
Insulation fault locator with 6 integrated measuring current transformers for localisation of insulation faults in main circuits
Insulation fault locator with 6 integrated measuring current transformers for localisation of insulation faults in control circuits
Portable insulation fault location systems for unearthed and earthed systems (IT and TN systems)
Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor
Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor
Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor with one alarm contact per channel
Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor with one alarm contact per channel
Universal measuring device with numerous measured quantities, energy and power measurement with storage, Power Quality Monitoring, limit value monitoring with alarm forwarding
AC/DC sensitive measuring current transformer (Type B)
Undervoltage/overvoltage relay for monitoring three-phase AC systems (window discriminator function)
Insulation monitoring device for inverter applications and large industrial plants
Insulation monitoring device for unearthed AC/DC control circuits
Insulation fault locator for localisation of insulation faults in main circuits
Insulation fault locator for localisation of insulation faults in control circuits
- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.
- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.
- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.
- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.
- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.
- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.
- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.
- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.
- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.
Insulation fault locator with 6 integrated measuring current transformers for localisation of insulation faults in main circuits
Insulation fault locator with 6 integrated measuring current transformers for localisation of insulation faults in control circuits
Portable insulation fault location systems for unearthed and earthed systems (IT and TN systems)
Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor
Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor
Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor with one alarm contact per channel
Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor with one alarm contact per channel
Universal measuring device with numerous measured quantities, energy and power measurement with storage, Power Quality Monitoring, limit value monitoring with alarm forwarding
AC/DC sensitive measuring current transformer (Type B)
Measuring relays and protection equipment - Part 1: Common requirements
Measuring relays and protection equipment - Part 127: Functional requirements for over/under voltage protection
Safety requirements for secondary batteries and battery installations - Part 2: Stationary batteries
Electrical safety in low voltage distribution systems up to 1 000 v a.c. and 1 500 v d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems.
Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems
Electrical safety in low voltage distribution systems up to 1000 V ac and 1500 V dc - Equipment for testing, measuring or monitoring of protective measures - Part 15: Functional safety requirements for insulation monitoring devices in IT systems and equipment for insulation fault location in IT systems