Harbor

Making ports electrically safe

Gantry cranes

Safely lifting loads and controlling cranes

Bender works in close cooperation with the manufacturers of gantry crane systems to optimise protection against electrical faults and guarantee the safety of the operating personnel. Insulation monitoring or residual current monitoring ensure high levels of safety and availability.

 

Request advice

Terminals

A high level of fire and personnel protection at the terminal

By means of insulation monitoring or residual current monitoring, Bender ensures the highest possible level of safety for people and systems and therefore guarantees a high level of system availability during embarking and disembarking or rather loading and unloading.

 

Request advice

Marinas, yacht harbours

Preventing damage due to fault currents

Moorings are often problematic in marinas. A central power supply feeds a large number of moorings, but there is no residual current monitoring for the individual moorings. This can lead to undetected fault currents being conducted from one boat through the water and damaging other boats in the process. Central shutdown via an RCD (fault current circuit breaker) means all moorings are de-energised, even if there is an electrical fault on one mooring only.

 

Request advice

Downloads

NameCategorySizeLanguageTimestampD-/B-Number
Product Overview ISOMETER®/ISOSCAN® Product Overviews 5.3 MB EN2024/02/1616.02.2024
Product Overview - Residual Current Monitoring Product Overviews 6.3 MB EN2024/10/2929.10.2024
Megayacht - Residual current monitoring in the luxury segment Market Segment Brochures 1.1 MB EN2024/02/2222.02.2024
Electrical Safety in Control and Auxiliary Circuits Technical article 632.6 KB EN2019/05/1313.05.2019

Products

Residual current monitoring

LINETRAXX® RCMS460-D
LINETRAXX® RCMS460-D

Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor

LINETRAXX® RCMS460-L
LINETRAXX® RCMS460-L

Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor

LINETRAXX® RCMS490-D
LINETRAXX® RCMS490-D

Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor with one alarm contact per channel

LINETRAXX® RCMS490-L
LINETRAXX® RCMS490-L

Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor with one alarm contact per channel

Insulation monitoring

ISOMETER® iso685…
ISOMETER® iso685…

Insulation monitoring device for inverter applications and large industrial plants

Current transformers

LINETRAXX® CTUB100 series

AC/DC sensitive measuring current transformer (Type B)

Neutral Grounding Resistance (NGR) Monitoring

LINETRAXX® NGRM700

The advanced Neutral Grounding Resistor Monitor for sophisticated applications

Residual current monitoring

LINETRAXX® RCMS460-D
LINETRAXX® RCMS460-D

Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor

Details
LINETRAXX® RCMS460-L
LINETRAXX® RCMS460-L

Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor

Details
LINETRAXX® RCMS490-D
LINETRAXX® RCMS490-D

Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor with one alarm contact per channel

Details
LINETRAXX® RCMS490-L
LINETRAXX® RCMS490-L

Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor with one alarm contact per channel

Details

Insulation monitoring

ISOMETER® iso685…
ISOMETER® iso685…

Insulation monitoring device for inverter applications and large industrial plants

Details

Current transformers

LINETRAXX® CTUB100 series

AC/DC sensitive measuring current transformer (Type B)

Details

Neutral Grounding Resistance (NGR) Monitoring

LINETRAXX® NGRM700

The advanced Neutral Grounding Resistor Monitor for sophisticated applications

Details

Standards

DIN IEC/TS 61439-7

Low-voltage switchgear and controlgear assemblies - Part 7: Assemblies for specific applications such as marinas, camping sites, market squares, electric vehicles charging stations

EN 61557-8

Electrical safety in low voltage distribution systems up to 1 000 v a.c. and 1 500 v d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems.

EN 61557-9

Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems

EN 61557-15

Electrical safety in low voltage distribution systems up to 1000 V ac and 1500 V dc - Equipment for testing, measuring or monitoring of protective measures - Part 15: Functional safety requirements for insulation monitoring devices in IT systems and equipment for insulation fault location in IT systems

Seminare

No news available.
qhy4raey

Do you have any questions?

Please contact us! We are here to help.

TO CONTACT FORM