The NGRM550 Neutral Grounding Resistor Monitor detects grounding-resistor failures and ground faults. It is intended for use in low-resistance grounded transformers and generators used in commercial and industrial power systems. In these systems, the NGRM550 monitors:
A benefit to many users is the multilingual user interface that allows the comfort of reading values and programming in your native language.
It is an ideal solution that is easy to retrofit into existing LRG applications or factory-install in new LRG packages. If customers prefer, they can easily program the relay via the built-in webserver. NGRM550’s can easily connect to a supervisory system with Modbus TCP/IP or RTU communications. Capabilities extend to 25 kV and 2,000 A.
The NGRM550 Neutral Grounding Resistor Monitor detects grounding-resistor failures and ground faults. It is intended for use in low-resistance grounded transformers and generators used in commercial and industrial power systems. In these systems, the NGRM550 monitors:
A benefit to many users is the multilingual user interface that allows the comfort of reading values and programming in your native language.
It is an ideal solution that is easy to retrofit into existing LRG applications or factory-install in new LRG packages. If customers prefer, they can easily program the relay via the built-in webserver. NGRM550’s can easily connect to a supervisory system with Modbus TCP/IP or RTU communications. Capabilities extend to 25 kV and 2,000 A.
Type | Tension d'alimentation US / Gamme de fréquence Hz | Réf. |
---|---|---|
NGRM550 | AC 48…240 V, 40…70 Hz DC 48…240 V | B94013550 |
Résistance de couplage CD…
Type | Tension Usys | Réf. |
---|---|---|
CD1000 | 400…690 V | B98039010 |
CD1000-2 | 400…1000 V | B98039053 |
CD5000 | 1000…4200 V | B98039011 |
CD14400 | 4300…14550 V | B98039054 |
CD25000 | 14551…25000 V | B98039055 |
Transformateur de courant de mesure
Type | Tension / courant | Réf. |
---|---|---|
CTAC35 CTAC60 CTAS50 CTAS80 CTAS120 | AC jusqu'à 30 A | B98110007 B98110017 B98110009 B98110010 B98110011 |
CTUB103-CTBC35 | AC/DC bis 10 A | B78120030 |
CTUB103-CTBC60 CTUB103-CTBC120 | AC/DC jusqu'à 25 A | B78120031 B78120032 |
CTB31…CTB51 série | AC > 30…1000 A | B980860xx |
Tension d'alimentation pour transformateur de courant de mesure CTUB103…
Type | Nombre maximal de transformateurs de courant raccordés | Réf. |
---|---|---|
STEP-PS/1 AC/24 DC/0.5 | 2 | B94053110 |
STEP-PS/1 AC/24 DC/1.75 | 7 | B94053111 |
STEP-PS/1 AC/24 DC/4.2 | 17 | B94053112 |
Nom | Type | Taille | Langue | Horodatage | D-/B-Numéro |
---|---|---|---|---|---|
NGRM550 Update V4.00 | Logiciels | 8.1 Mo | 2024/04/2323.04.2024 | ||
NGR Product Comparison | Dépliants | 630.6 Ko | EN | 2022/07/1818.07.2022 | |
NGRM…-Modbus | Manuels | 453.9 Ko | DE | 2022/06/0909.06.2022 | D00292 |
NGRM…-Modbus | Manuels | 443.2 Ko | EN | 2022/06/0909.06.2022 | D00292 |
NGRM…-Modbus | Manuels | 463.4 Ko | ES | 2022/06/0909.06.2022 | D00292 |
NGRM500/NGRM550 | Notices | 1.2 Mo | DE | 2023/06/2020.06.2023 | D00373 |
NGRM500/NGRM550 | Notices | 1.2 Mo | FR | 2023/06/2020.06.2023 | D00373 |
NGRM500/NGRM550 | Notices | 1.2 Mo | EN | 2023/06/2020.06.2023 | D00373 |
NGRM500/NGRM550 | Quickstarts | 1.1 Mo | DE | 2024/02/0707.02.2024 | D00373 |
NGRM500/NGRM550 | Quickstarts | 1.1 Mo | EN | 2024/02/0707.02.2024 | D00373 |
NGRM500/NGRM550 | Manuels | 7.4 Mo | DE | 2024/09/1818.09.2024 | D00373 |
NGRM500/NGRM550 | Manuels | 7.4 Mo | EN | 2024/09/1818.09.2024 | D00373 |
NGR Checklist (US) | Informations techniques | 245.3 Ko | EN | 2022/11/0707.11.2022 | |
NGRM550 & NGRM750 | Dépliants | 630.6 Ko | EN | 2022/05/2525.05.2022 | |
NGRM550 & NGRM750 | Dépliants | 597.5 Ko | ES | 2022/05/2525.05.2022 |