ISOMETER® isoCHA425HV with AGH420-1/AGH421-1

  • Switchable between CCS (Combined Charging System) and CHAdeMO
  • Nominal voltages up to DC 1000 V
  • Detection of symmetrical and asymmetrical insulation faults
  • Electrically isolated Modbus RTU interface
  • Display of the fault location (DC+/DC/balanced)

The ISOMETER® isoCHA425HV in combination with the AGH420-1/AGH421-1 coupling device monitors the insulation resistance RF for DC fast charging stations according to the CHAdeMO standard or according to the Combined Charging System (CCS) for nominal system voltage ranges between DC 0 V and 1000 V.

In order to meet the requirements of the applicable standards, customised parameter settings must be made on the equipment in order to adapt it to local equipment and operating conditions. Please heed the limits of the range of application indicated in the technical data.

Any other use or a use that goes beyond this constitutes improper use.

Questions? Contact us!

ISOMETER® isoCHA425HV mit AGH420-1
ISOMETER® isoCHA425HV mit AGH420-1
  • Switchable between CCS (Combined Charging System) and CHAdeMO
  • Nominal voltages up to DC 1000 V
  • Detection of symmetrical and asymmetrical insulation faults
  • Electrically isolated Modbus RTU interface
  • Display of the fault location (DC+/DC/balanced)

The ISOMETER® isoCHA425HV in combination with the AGH420-1/AGH421-1 coupling device monitors the insulation resistance RF for DC fast charging stations according to the CHAdeMO standard or according to the Combined Charging System (CCS) for nominal system voltage ranges between DC 0 V and 1000 V.

In order to meet the requirements of the applicable standards, customised parameter settings must be made on the equipment in order to adapt it to local equipment and operating conditions. Please heed the limits of the range of application indicated in the technical data.

Any other use or a use that goes beyond this constitutes improper use.

Questions? Contact us!

We need your consent to load the YouTube Video service!

We use a third party service to embed video content that may collect data about your activity. Please review the details and accept the service to watch this video.

powered by Usercentrics Consent Management Platform

Features

  • Monitoring of the insulation resistance RF of DC charging stations according to CHAdeMO standard or Combined Charging System (CCS)
  • CHAdeMO (Mode CHd and CHA):
    – Maximum system leakage capacitance 1.6 μF per conductor
    – Detection of insulation faults in the system voltage range 50 V to 1000 V
    – One-pole insulation faults RFU: RFU≤ 100 kΩ: Response time ≤ 1 s, 100 kΩ < RFU≤ 2 MΩ: Response time ≤ 10 s – Two-pole insulation faults RFS: RFS ≤ 160 kΩ: Response time ≤ 10 s, RFS > 160 kΩ (200 kΩ): no detection (Deactivation) (only CHd)
  • CCS (Mode dc):
    – Detection of insulation faults up to 2 MΩ
    – Maximum system leakage capacitance Ce: 20 μF
    – Response time tan at Ce ≤ 5 μF or RF ≤ 100 kΩ: ≤ 10 s
  • Measurement of the system leakage capacitance Ce
  • Measurement of the nominal system voltage Un (True RMS) with undervoltage/overvoltage detection
  • Measurement of the DC residual voltages UL1e (between L1/+ and earth) as well as UL2e (between L2/- and earth)
  • Selectable start-up delay, response delay and delay on release
  • Two separately adjustable response value ranges of 5...600 kΩ (Alarm 1, Alarm 2)
  • Alarm signalling via LEDs (“AL1”, “AL2”), a display and alarm relays (“K1”, “K2”)
  • Automatic device self test with connection monitoring
  • Selectable N/C or N/O relay operation
  • Measured value indication via a multifunctional LC display
  • Fault memory can be activated
  • RS-485 (galvanically isolated) including the following protocols:
    – BMS interface (Bender measuring device interface) for data exchange with other
  • Bender components
    – Modbus RTU
    – IsoData (for continuous data output)
  • Password protection to prevent unauthorised parameter changes
  • Stop mode for disabling the measuring pulse generator and in combination with AGH421-1 disconnection from the monitored system.

Applications

  • DC charging stations for electric vehicles in accordance with the Japanese charging standard CHAdeMO
  • DC charging stations for electric vehicles according to CCS (Combined Charging System) in compliance with IEC 61851-23

ISOMETER® isoCHA425HV with AGH420-1/AGH421-1 Variant(s)

TypeNominal voltage UnArt. No.
Set
Art. No.
Contents
isoCHA425HV-D4-4 + AGH420-1CCS: DC 0…1000 V
CHAdeMO: DC 50…1000 V
B71036396B71036394
B78039033
isoCHA425HV-D4-4 + AGH421-1CCS: DC 0…1000 V
CHAdeMO: DC 50…1000 V
B71036399B71036394
B78039034

Optional Accessories for ISOMETER® isoCHA425HV with AGH420-1/AGH421-1

TypeArt. No.
Mounting clip for screw mounting (one piece per device)B98060008
Mounting frame XM420B990994 

Downloads for ISOMETER® isoCHA425HV with AGH420-1/AGH421-1

NameCategorySizeLanguageTimestampD-/B-Number
isoCHA425HV avec AGH420-1/AGH421-1 Product Brochures 1.5 MB FR2024/09/1010.09.2024
RoHS/REACH Report - B71036396 RoHS/REACH Report 252.8 KB 2024/09/0606.09.2024
We are your eMobility partner! Flyer 262.3 KB 2023/11/2929.11.2023
isoCHA425 CE Declarations of conformity 87.4 KB 2024/04/1818.04.2024
UKCA - isoCHA425 Declarations of Conformity 121.5 KB 2024/04/2323.04.2024
isoCHA425HV with AGH420-1/AGH421-1 Product Brochures 1.5 MB 2024/07/0101.07.2024
AGH421 Manuals 1.5 MB DE2023/10/3131.10.2023D00173
AGH421 Manuals 1.5 MB EN2023/10/3131.10.2023D00173
AGH420 Manuals 1.5 MB DE2023/10/3131.10.2023D00029
AGH420 Manuals 1.5 MB EN2023/10/3131.10.2023D00029
isoCHA425HV Application note 276.7 KB 2023/06/2929.06.2023D00404
isoCHA425HV Datasheets 4.0 MB DE2024/04/0808.04.2024D00404
isoCHA425HV Datasheets 4.0 MB EN2024/04/0808.04.2024D00404
isoCHA425HV Manuals 4.8 MB EN2024/04/0808.04.2024D00404
isoCHA425HV Manuals 4.8 MB DE2024/04/0808.04.2024D00404
isoCHA425HV (US) Flyer 794.2 KB EN2021/03/1111.03.2021
isoCHA425HV Quickstarts 1.0 MB DE2024/05/2323.05.2024D00404
isoCHA425HV Quickstarts 1.0 MB EN2024/05/2323.05.2024D00404