ICC1314 Charge controller

  • Integrated dynamic load management (DLM)
  • Regular SW updates
  • PLC according to ISO 15118
  • WiFi, Ethernet and 4G modem on board
  • Patented 6 mA DC fault current detection
  • Very compact PCB design (120 mm x 100 mm)

The ICC1314 is a charge controller with the latest hardware design that combines many functions in a very small space. The ICC1314 is a compact version of the ICC1324 without an integrated power supply unit.

The ICC1314 measures just 120 mm x 100 mm and therefore harmonises perfectly with the Power Module IPM1300 for setting up highly integrated charging stations.

In conjunction with an additional ICC1314 (companion variant), it is easy to realise double charging stations.

This means it can be used flexibly in charging stations and wallboxes for all application scenarios: for public, semi-public and private use.

As a charge controller, the ICC1314 has Wi-Fi, a 4G modem and Ethernet connections and masters all important communication protocols such as OCPP, EEBUS, SMA SEMP and Modbus TCP.

All protection functions required by standards are supported by the combination of ICC1314 and IPM1300: 6 mA DC fault current detection, monitoring of the protective conductor, overvoltage protection and rotating field detection. The integrated weld check is a function for detecting welded relay contacts and can control a disconnecting device.

The ICC1314 is future-proof thanks to its support of ISO 15118 including Plug&Charge certification by Hubject. The EEBus protocol is supported for grid-friendly control in accordance with §14a EnWG.

The integrated dynamic load management (DLM) manages up to 250 charging stations and enables the realisation of large and complex charging infrastructures.

Connection to existing PV systems is flexibly possible thanks to the integrated solar DLM function. This makes it easy to realise a PV charging function or PV surplus charging. The user can conveniently choose between these operating modes via an app.

Questions? Contactez-nous!

ICC1314
ICC1314
ICC1314
ICC1314
  • Integrated dynamic load management (DLM)
  • Regular SW updates
  • PLC according to ISO 15118
  • WiFi, Ethernet and 4G modem on board
  • Patented 6 mA DC fault current detection
  • Very compact PCB design (120 mm x 100 mm)

The ICC1314 is a charge controller with the latest hardware design that combines many functions in a very small space. The ICC1314 is a compact version of the ICC1324 without an integrated power supply unit.

The ICC1314 measures just 120 mm x 100 mm and therefore harmonises perfectly with the Power Module IPM1300 for setting up highly integrated charging stations.

In conjunction with an additional ICC1314 (companion variant), it is easy to realise double charging stations.

This means it can be used flexibly in charging stations and wallboxes for all application scenarios: for public, semi-public and private use.

As a charge controller, the ICC1314 has Wi-Fi, a 4G modem and Ethernet connections and masters all important communication protocols such as OCPP, EEBUS, SMA SEMP and Modbus TCP.

All protection functions required by standards are supported by the combination of ICC1314 and IPM1300: 6 mA DC fault current detection, monitoring of the protective conductor, overvoltage protection and rotating field detection. The integrated weld check is a function for detecting welded relay contacts and can control a disconnecting device.

The ICC1314 is future-proof thanks to its support of ISO 15118 including Plug&Charge certification by Hubject. The EEBus protocol is supported for grid-friendly control in accordance with §14a EnWG.

The integrated dynamic load management (DLM) manages up to 250 charging stations and enables the realisation of large and complex charging infrastructures.

Connection to existing PV systems is flexibly possible thanks to the integrated solar DLM function. This makes it easy to realise a PV charging function or PV surplus charging. The user can conveniently choose between these operating modes via an app.

Questions? Contactez-nous!

Caractéristiques

  • Charge controller in accordance with IEC 61851-1 (charging mode 3)
  • Can be integrated into single-phase or three-phase grids up to 3x 32 A
  • Master/slave operation can be configured for setting up charging stations with two charging connectors:
    - An ICC1314-Connect-Plus charger controller with 4G modem as a data gateway or router
    - An ICC1314-Companion without a 4G modem as a client
  • Patented DC residual current monitoring module (external RCD type A required)
  • Integrated emergency opener for motor control (locking/unlocking)
  • Integrated Wi-Fi module and two Ethernet interfaces (Connect Plus)
  • One or two USB host interfaces (type A) (Companion or Connect Plus)
  • USB CONFIG interface (type B) for local configuration and importing software updates
  • Additional inputs and outputs for extended control of the charge controller
  • Additional control of SCHUKO socket outlets
  • Counter interface: Modbus (TCP/IP and RTU)
  • Internal environmental sensors for temperature and tilt
  • ISO 15118 Powerline Communication (PLC) for plug & charge, car charging and load management systems
  • Control Pilot and Proximity Pilot communication (in accordance with IEC 61851-1)
  • OCPP 1.6+ (JSON)
  • Integrated dynamic load management (DLM), hierarchical DLM and solar DLM with up to 250 charging stations
  • Integration into external energy management systems via EEBUS, Modbus (TCP/IP), SMA-SEMP or OCPP
  • Suitable for the development of charging stations that comply with calibration law

Applications

  • AC charging stations for electric vehicles, wallboxes, single and double charging stations

ICC1314 Charge controller Variante(s)

TypeUSB4G modemEthernetWiFiPLC*Isolated
Inputs
12 V
Switching
Output
Art. No.
ICC1314-Connect-Plus-G12x (type A)
1x (type B)

(Cat 1)
222B94060030
ICC1314-Companion-G11x (type A)
1x (type B)
------22B94060031

* Powerline Communication according to ISO/ IEC15118

Accessoires en option pour ICC1314 Charge controller

TypeArt. No.
IPM1300B94060198
HMI150 Interface moduleB94060150
HMI145 Interface moduleB94060151
HMI140 Interface moduleB94060152

Téléchargements pour ICC1314 Charge controller

NomTypeTailleLangueHorodatageD-/B-Numéro
Länderliste Funkzulassungen/Countries with RF Approval Informations techniques 85.5 Ko 2024/12/1313.12.2024